Rki-instruments RM-5000 Series Indicator/Alarm Unit Bedienungsanleitung Seite 33

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 81
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 32
5 How to Operate 5-3. How to start the indicator/alarm unit
- 33 - RM-5000
5-3. How to start the indicator/alarm unit
Before turning on the power switch, check whether the indicator/alarm unit is installed properly.
Open the front cover of the indicator/alarm unit to find the power switch.
Turn ON the power switch.
After the indicator/alarm unit completes the start-up, it enters the detection mode swiftly.
<<Start-up Procedures (approximately 25 seconds for system check of the indicator/alarm unit and alarm
deactivation)>>
Power switch
Front cover
OFF
ON
Slide
During maintenance
During inhibit
Lamp on
Lamp off
Lamp blinking
Power-on
(All lights ON)
Initial clear
Gas specifications display
(Gas name and full scale value)
Detection mode
(Gas name, detected
concentration value)
Seitenansicht 32
1 2 ... 28 29 30 31 32 33 34 35 36 37 38 ... 80 81

Kommentare zu diesen Handbüchern

Keine Kommentare