www.rkiinstruments.comSC-01Operator’s ManualPart Number: 71-0136RKRevision: BReleased: 10/20/11

Seite 2 - SC-01 Operator’s Manual

5 • Description SC-01 Operator’s ManualProtective Rubber BootA rubber boot installed over the case helps protects the SC-01. The boot allows viewing

Seite 3 - Warranty

SC-01 Operator’s Manual Description • 6Alligator and Belt ClipsThe SC-01 is available with two types of clips, the standard alligator clip and the op

Seite 4 - Table of Contents

7 • Description SC-01 Operator’s ManualSensorThe SC-01 is capable of accepting a variety of toxic gas sensors. The sensor is cylindrically shaped wit

Seite 5

SC-01 Operator’s Manual Description • 8Printed Circuit BoardsThe primary function of the SC-01 printed circuit boards is to amplify the signal sent t

Seite 6 - Introduction

9 • Description SC-01 Operator’s Manualalkaline batteries last at least 250 hours. The battery icon on the LCD shows remaining battery life. When the

Seite 7 - Specifications

SC-01 Operator’s Manual Start Up • 10Start UpThis section explains how to start up the SC-01 and to get it ready for operation.Start-up Procedure1. P

Seite 8

11 • Start Up SC-01 Operator’s ManualCAUTION: If the instrument gives a low battery warning or dead battery alarm, change the alkaline batteries befo

Seite 9 - Description

SC-01 Operator’s Manual Start Up • 124. Release the AIR ▼ button when the LCD displays “RELEASE” in the upper left corner. 5. The unit will take a fe

Seite 10 - Protective Rubber Boot

13 • Operation in Measuring Mode SC-01 Operator’s ManualOperation in Measuring ModeThis section covers the operation of the SC-01 in Measuring Mode.

Seite 11 - Sensor Retainer

SC-01 Operator’s Manual Operation in Measuring Mode • 142. Press and release the ▲ DISP button to enter Display Mode. The LCD backlight will activate

Seite 12 - Control Buttons

SC-01 Operator’s ManualWARNINGRead and understand this instruction manual before operating instrument. Improper use of the gas monitor could result i

Seite 13 - Batteries

15 • Operation in Measuring Mode SC-01 Operator’s ManualTable 3: Alarm Types and IndicationsAlarm Type LCD Indications Other IndicationsWarningConcen

Seite 14

SC-01 Operator’s Manual Operation in Measuring Mode • 16Resetting Gas AlarmsTo reset a gas alarm, press and release the POWER button after the gas re

Seite 15 - Start Up

17 • Operation in Measuring Mode SC-01 Operator’s Manual4. If the over range condition continues, you may need to replace the sensor.5. If the over r

Seite 16

SC-01 Operator’s Manual Operation in Measuring Mode • 18Using the SC-01 With the Optional Extender CableThe SC-01 can be used with an optional extend

Seite 17 - GOOD-BYE

19 • Operation in Measuring Mode SC-01 Operator’s Manual4. If the sensor retainer slides out with the sensor, pull the sensor out of the bottom of th

Seite 18 - Operation in Measuring Mode

SC-01 Operator’s Manual Operation in Measuring Mode • 2012.With the extender cable plug gently touching sensor socket, turn the extender cable plug c

Seite 19

21 • Data Logging SC-01 Operator’s ManualData LoggingThe SC-01 features the ability to log data to its internal memory and download it to a computer

Seite 20

SC-01 Operator’s Manual Setup Mode • 22Setup ModeThis section describes the SC-01 in Setup Mode. In Setup Mode, you can move through a menu of screen

Seite 21

23 • Setup Mode SC-01 Operator’s Manual1. When the DATE Screen is displayed, press and release the POWER button. A screen appears with the year flash

Seite 22

SC-01 Operator’s Manual Setup Mode • 243. Press and hold the AIR ▼ button. The LCD displays “hold” prompting you to hold the AIR ▼ button.4. After a

Seite 23 - Cable Retainer

SC-01 Operator’s Manual WarrantyWarrantyRKI Instruments, Inc. warrants the SC-01 Single Gas Monitor sold by us to be free from defects in materials,

Seite 24

25 • Setup Mode SC-01 Operator’s ManualWARNING: Calibrate the SC-01 in a non-hazardous environment.1. Before performing a span adjustment, perform a

Seite 25

SC-01 Operator’s Manual Setup Mode • 263. Confirm that the regulator on/off knob is turned all the way clockwise (closed) and screw the calibration g

Seite 26 - Data Logging

27 • Setup Mode SC-01 Operator’s Manual11. If the span adjustment is successful, the LCD will show the following screen before returning to the SPAN

Seite 27 - Setup Mode

SC-01 Operator’s Manual Setup Mode • 28NOTE: The sensor has the standard alarm points saved in its memory. Changing the alarm points in this menu ite

Seite 28 - PUSH AIR

29 • Setup Mode SC-01 Operator’s Manualsetpoint. The unit will proceed to the TWA Screen. The TWA setpoint is flashing.8. Use the AIR ▼ and ▲ DISP bu

Seite 29 - SPAN CAL

SC-01 Operator’s Manual Setup Mode • 30Updating the Calibration FrequencyEntering the CAL. LIMIT menu item allows you to change the calibration frequ

Seite 30

31 • Maintenance SC-01 Operator’s ManualMaintenanceThis section discusses calibration of the SC-01 and describes troubleshooting procedures for the S

Seite 31 - SPAN VALUE

SC-01 Operator’s Manual Maintenance • 32Table 7: Troubleshooting the 01 SeriesSymptoms Probable Causes Recommended Action• The LCD is blank. • The un

Seite 32

33 • Maintenance SC-01 Operator’s ManualReplacing the BatteriesWARNING: To prevent ignition of a hazardous atmosphere, batteries must only be changed

Seite 33

SC-01 Operator’s Manual Maintenance • 345. Reinstall the battery cover.NOTE: If the unit has been without batteries or if the old batteries have been

Seite 34

Table of Contents SC-01 Operator’s ManualTable of ContentsIntroduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Seite 35 - CAL. LIMIT

35 • Maintenance SC-01 Operator’s Manual6. With the sensor plug gently touching sensor socket, turn the sensor clockwise or counterclockwise while pu

Seite 36 - Maintenance

SC-01 Operator’s Manual Maintenance • 36CAUTION: Do not force the sensor into the sensor socket. Forcing a sensor into the sensor socket may damage t

Seite 37

37 • Maintenance SC-01 Operator’s Manual11. Press and briefly hold the POWER button until you hear a beep to turn on the SC-01. After a few seconds,

Seite 38 - Replacing the Batteries

SC-01 Operator’s Manual Parts List • 38Parts ListTable 8 lists replacement parts and accessories for the SC-01.Table 8: Parts ListPart Number Descrip

Seite 39 - Replacing the Sensor

39 • Parts List SC-01 Operator’s Manual81-0196RK-04 Calibration cylinder, 10 ppm HCN in nitrogen, 34 liter81-1051RK Regulator, fixed flow, w/gauge &a

Seite 40 - Sensor Opening

SC-01 Operator’s Manual Parts List • 40ESM-01DH-ASH3 Sensor, AsH3 (arsine), 0 - 1.50 ppm, diffusion only typeESM-01DH-D-HCN Sensor, HCN (hydrogen cya

Seite 41 - Retainer

SC-01 Operator’s Manual Table of ContentsMaintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Seite 42 - GAS CHANGE

1 • Introduction SC-01 Operator’s ManualIntroductionUsing an advanced microprocessor controlled detection system, the SC-01 Personal Single Gas Monit

Seite 43 - Parts List

SC-01 Operator’s Manual Specifications • 2SpecificationsTable 1: 01 Series SpecificationsAvailable Target Gas/Detection Range/Display Increment• Ammo

Seite 44

3 • Specifications SC-01 Operator’s ManualOperating Temp. & Humidity14°F to 104°F (-10°C to +40°C), below 95% RH (non condensing)Table 1: 01 Seri

Seite 45

SC-01 Operator’s Manual Description • 4DescriptionThis section describes the components of the SC-01. These components include the SC-01’s protective