RKI Instruments M2 Betreibershandbuch

Stöbern Sie online oder laden Sie Betreibershandbuch nach Nein RKI Instruments M2 herunter. RKI Instruments M2 Operator`s manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 11
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
www.rkiinstruments.com
30-0954RK-200 Series Sample Draw
Aspirator Adapter
Operators Manual
Part Number: 71-0188RK
Revision: E
Released: 5/16/12
Seitenansicht 0
1 2 3 4 5 6 ... 10 11

Inhaltsverzeichnis

Seite 1 - Operator’s Manual

www.rkiinstruments.com30-0954RK-200 Series Sample DrawAspirator Adapter Operator’s ManualPart Number: 71-0188RKRevision: EReleased: 5/16/12

Seite 2

7 • 30-0954RK-200 Series Sample Draw Aspirator Adapter3. Make sure that all personnel and equipment are clear of the inlet end of the sample line.4.

Seite 3 - Product Warranty

30-0954RK-200 Series Sample Draw Aspirator Adapter • 8Parts ListTable 2 lists replacement parts and accessories for the sample draw adapter.Table 2:

Seite 4 - Description

30-0954RK-200 Series Sample Draw Aspirator AdapterWARNINGRead and understand this instruction manual before operating detector. Improper use of the d

Seite 5 - Detector Head(s)

30-0954RK-200 Series Sample Draw Aspirator AdapterProduct WarrantyRKI Instruments, Inc. warrants gas alarm equipment sold by us to be free from defec

Seite 6

1 • 30-0954RK-200 Series Sample Draw Aspirator AdapterOverviewThis manual describes the 30-0954RK-200 Series sample draw aspirator adapter. It also d

Seite 7 - Installation

30-0954RK-200 Series Sample Draw Aspirator Adapter • 2Figure 2: Component LocationThe sample draw adapter consists of eleven major components (see Fi

Seite 8

3 • 30-0954RK-200 Series Sample Draw Aspirator AdapterRegulatorThe regulator has an inlet port on its left side with a 1/4” tube fitting. The maximum

Seite 9 - Blowback Operation

30-0954RK-200 Series Sample Draw Aspirator Adapter • 4The drain fault switch senses a break or very low flow in the water drain line and provides ope

Seite 10

5 • 30-0954RK-200 Series Sample Draw Aspirator Adapterdetector head’s cover, and to bring power/signal wiring to the detector head. Also provide suff

Seite 11 - Parts List

30-0954RK-200 Series Sample Draw Aspirator Adapter • 6Figure 5: Low Flow and Drain Fault Wiring, Parallel Wiring4. Start up the detector head(s) as d